Series capacitive compensation

M Eremia, S Nilsson - … in Power Systems: HVDC, FACTS, and …, 2016 - Wiley Online Library
… scheme of the series capacitor compensation installation [1]. … for which the thyristor valve,
the reactor, and capacitor banks … In the bus admittance matrix [Ynn], the transversal element im …

… current limiter using vacuum arc current commutation. Phase 2. Maximizing the current rating of a single 72-kV device using a minimum amount of parallel capacitance …

CW Kimblin, JG Gorman, FA Holmes, PR Emtage… - 1979 - osti.gov
… the fault current rise, and the subsequent application of a transverse … the cost of newly installed
equipment. In addition, it can overstress … The effect of the saturable reactor under current

Adaptive power supply system in plot with artificially complex profile

M Yakubov, M Sagatova, S Norjigitov… - E3S Web of …, 2023 - e3s-conferences.org
… the restriction of passenger and freight traffic through the … of an additional installation of
transverse compensation, the use of … the installation site of the reactor 𝐿𝑘 compensating devices …

Transient fault currents in HVDC VSC networks during pole-to-ground faults

MK Bucher - 2014 - research-collection.ethz.ch
… due to converter reactive power compensation by the series … Vdc using a phase reactor Ls
and a DC capacitor Ccap. High … pole conductors have to be installed. In contrast to the bipolar …

[HTML][HTML] Method of Reducing the Effects of Repeated Ignition during Earth Faults in Compensated Medium Voltage Networks

J Andruszkiewicz, J Lorenc, B Olejnik, A Weychan… - Energies, 2023 - mdpi.com
Transverse (earth) conductance G 0 results from the resultant … of matching of the shunt
reactor to the capacitance and on the … circuit of the additional resistance installed. The proposed …

DC and AC power grids with alternative energy sources-2. Lecture notes

IV Verbytskyi - 2021 - ela.kpi.ua
… grids, reactive power compensation and elimination of power … find the voltage drop across
the transverse elements of the line … of which a capacitive filter is installed. Therefore, the input …

Analysis and optimized design of a novel compact orthogonal controllable reactor

J Yuan, X Zheng, F Chen - IEEE Transactions on Power …, 2022 - ieeexplore.ieee.org
… so as to achieve dynamic compensation of the line reactive power … 1 and 2, the installation
space of the traditional topology is … curve in the transverse direction. The minimum value of the …

[PDF][PDF] Research on the power grid operation improvement by static VAR compensators

V Komen, M Blasina, R Cucic - Tehnicki Vjesnik, 2012 - core.ac.uk
… -controlled reactor (TCR) and a thyristor-switched capacitor (… the current injected by SVC,
which requires installation of … associated reactances in the longitudinal and transversal axis. …

Voltage control and compensation of reactive power by SVC devices

M Blasina, V Komen, R Ćućić - Engineering Review: Međunarodni …, 2010 - hrcak.srce.hr
… their influence on the voltage waveform and the current at the … /off switching of the transverse
capacitor, thus allowing step … reactor should be installed in a series with the capacitor and …

Blocking of Control of the Circuit Breaker in the Presence of a Dangerous Aperiodic Component in the Total Current of the Circuit Breaker

NV Bespalko, YL Artsishevsky - 2020 3rd International Youth …, 2020 - ieeexplore.ieee.org
… overvoltage limiter, as well as for the isolation of reactors, … is installed in the neutral of each